ACT-60 · Replacement of inductive sensor wiring of the probe.
Description
With the machine turned off and disconnected from the tractor, remove the plastic probe fairing from the intercep, locate the inductive sensor that will be on a folded bracket pointing at the eccentric of the shaft. Remove the cable connected to the inductive and follow the cable along its route to the junction box by releasing the cable ties that hold it attached to the patch cords. Release the cable at its end of the junction box and replace it with a new one by bridling it to the hoses as the one that has been removed was.
Compatible machine families
BIOCOMBICULTIFRUTDAVICULTORFRONT-XLID-FRONTID-NAMICID-WEEDERID-XLVENTRALX-TREME
Maintenance that uses this task
| Maintenance | Machine families |
|---|---|
| MM-8 · Maintenance at 2,400 hours | AL-CALHALMOND-3BASIC-LBASIC-PBIOCOMBICONDORCULTIFRUTDAVICULTORDAVICULTOR 2.0DEADEFEAHECO-CUTECOFEEDECOTRIMEFIC-PFRONT-XLFRTI-DUSTI-GREENID-AID-DUALID-FRONTID-NAMICID-REVID-REXID-ROLLID-TERRAID-WEEDERID-XLLAT&GONAKIRIOLIXPFOPFPPFS-iPFS-i-CPROFEEDPRUNEXPV-LPV-L-RPV-SETOPV-TUNELPV-TUNEL-RPV-VIEWPV-VIEW-RPVORANNAREV-2RUNDERSURFEEDTD-FASTTD-KERRTD-LTD-RTD-SOTD-VIDTRIM-PROV-DUALV1V5VENTRALX-TREMEX10-TILLERgdgd |